VPARAMETER
program instruction
Syntax
MicroV+ VPARAMETER (sequence, tool, parameter, index, object) = value
V+
VPARAMETER (sequence, tool, parameter, index, object) $ip = value
Description
Sets the current value of a vision tool parameter.
Parameters
Details
Parameters sequence, tool, parameter, index, and object are optional. These parameters are 1-based.
If no value is provided for these parameters, they default to 1.
In V+ the vision server is the PC on which the AdeptSight vision software is running.
Example
; Set a Locator to find
; a maximum of 4 object instances
; MaximumInstanceCount = 519
VPARAMETER(1,2,519) = 4
sequence Index of the vision sequence. First sequence is '1'
tool Index of the tool in the sequence.
parameter Identifier (ID) of the parameter. Refer to the AdeptSight Quick Reference
tables to find the ID for the required parameter.
index Some parameters require an index. For example, the index of a model, of an
edge pair, or of a blob.
object Some parameters require an object index to access specific values in an array.
$ip IP address of the vision server.
Standard IP address format. For example 255.255.255.255.
This parameter applies to V+ syntax only.